Application
Acne Therapy
Wrinkle removal
Skin rejuvenation
Permanent hair removal
Reduction of pigmented lesions
Freckle, vascular lesions and facial blemish removal
Advantages
1. Germany Imported Lamp
2. Solenoid valve control, independent waterway heat dissipation;
3. Intelligent multi-functional platform to support a variety of technical treatment of head.
4. Three handles:Hair Removal Handle +Â Skin Rejuvenation Handle +Â Nd: Yag Laser Handle.
5. The shell is made of the ABS environmental material and beautiful design.
6. Long continuous work time, stable function, shot period of treatment
7. 10.4"colorful Touch Screen,rotating screen
8. 16 Multilingual Languages
Specification
Â
Operation Inteface | 10.4 inch TFT Screen |
Wavelength | 420-1200nm |
Working Mode  |
SHR Working &Â Laser working |
Spot Size | 15X50mm; 12X33mm(option for both handles) |
Energy   | 1-26J/cm2 (SHR & SSR) 300-1000mj (Laser) |
Pulse Width  |
1-15ms |
Frequency | 1-10Hz |
Pulse Amount | 1-15 |
Handle | 1X610-950nm(SHR); 1X420-1200nm(OPT) 1X Laser |
Main Drive Power | 2000WÂ |
Handpiece lifetime | 300,000 shots times for each handle |
Weight | 75KG |
Hair Growth Table
Â
Area | Appr.depths of terminal anagen follicle | Duration of TELOGEN | Duration of  ANAGEN | Number of follicles/cm2 | Daily rate of growth |
HEAD | Â | Â | Â | Â | Â |
Upper Lip | 1~2.5mm | 6 weeks | 4 months | 500 | Â |
Beard-Chin | 2~4mm | 10 weeks | 1 year | 500 | 0.38mm |
Cheeks | 2~4mm | Â | Â | 880 | 0.32mm |
Eyebrows | 2~2.5mm | 3 months | 4~8 weeks | Â | 0.16mm |
Ear | Â | 3 months | 4~8 weeks | Â | Â |
Scalp | 3~5mm | 3~4months | 2~6 years | 350 | 0.35mm |
BODY | Â | Â | Â | Â | Â |
Axillae | 3.5~4.5mm | 3 months | 4 months | 65 | 0.3mm |
Legs,Thighs | 2.5~4mm | 5 months | 4 months | 60 | 0.21mm |
Pubic Area | 3.5~5mm | 3 months | 4 months | 70 | Â |
Arms | Â | 4 months | 3 months | 80 | 0.3mm |
Breast | 3~4.5mm | Â | Â | 65 | 0.35mm |
Trunk | 2~4.5mm | Â | Â | 70 | 0.3mm |
Â
Plasma Sterilizer
Plasma sterilizer is to sterilize by hydrogen peroxide low-temperature plasma.Through sterilization,a certain method is used to inactivate various microorganisms on medical instruments and surgical instruments,thereby achieving the purpose of sterilization.
1,Medical plasma sterilizer: sterilization temperature of 50°C± 5°C,low temperature and no humidity,no damage to the sterilization articles and equipment,can extend the life of precision instruments.
2.Medical plasma sterilizer green and environmental protection:hydrogen peroxide solution is used as sterilizing agent,no toxic substance remains,no drainage or exhaust is required,no damage to the operator's body,and special filters for high efficiency can be applied to the air intake and exhaust ports.Absorption of H2O2 from the process of vacuum rejection will result in zero pollution to the environment.
3.Medical plasma sterilizer sterilization stability:The sterilization chamber is made of aluminum or stainless steel,which has advantages of anti-corrosion and thermal conductivity,which makes the temperature of the sterilization chamber more balanced and effective, and ensures that H2O2 maintains 100% of the gas throughout the process.The hydrogen peroxide low temperature storage system ensures that the hydrogen peroxide concentration is stable and effective and does not volatilize.
4.High sterilizing efficiency:The design of a rectangular sterilization chamber makes it possible to load more instruments at a time and make the use of the sterilization chamber more convenient.
SanQiang medical companies specializing production plasma sterilizer.
Plasma Sterilizer
Plasma Sterilizer,Low Temperature Plasma Sterilizer,Automatic Plasma Sterilizer,Medical Intelligent Sterilizer
Henan Sanqiang Medical Equipment Liability Co.,Ltd , http://www.sterilizers-china.com