Model NO.: SP-50B
Power Source: AC100-240V, 50/60Hz
Three Levels of Occlusion: High, Middle and Low
Three Work Modes: Rate Mode, Time Volume Mode, Dosage Weight Mode
Trademark: Brandnew
Transport Package: Standard Export Carton with Foam
Specification: Class I
Origin: Beijing, China
HS Code: 9018909000
Syringe PumpFeatures:
1. Audible and visual alarm for occlusion, empty, near empty, low battery, end of infusion, syringe loose, wrong setting etc, which gains patents
2. More Drug library
3. Compatible with 10ml, 20ml, 30ml, 50ml syringe of any brands
4. Preset Solution Volume to greatly reduce the workload of nurses
5. Three work modes: Rate mode, Time Volume mode, Dosage Weight mode
6. Three levels of occlusion: high, middle and low
7. Purge and Bolus function
8. KVO: KVOÂ (keep-vein-open) automatically opens as infusion is completed. And KVO rate can be modified from 0.1ml/h to 10ml/hÂ
9. Freely Stackable: freely stack one onto another to provide multiple Solutions, which have a wide range of clinical applications.
10. Connecting Port for Nurse-Paging
11. Power Source: AC100-240V, 50/60Hz; Internal Battery, DC12V car charge
12. One-key operation makes setup easy and simple
13. Syringe Plunger Grabble Detector, operable with one hand in a No-Germ Environment
14. Automatically record of Infusion
15. HD LCD Display, high capacity words, friendly user interface, dynamically display working status
16. Syringe brand can be displayed, furthermore, syringe specification can be written into the pump
17. language: English, Poland, Latvian, Russian etc
18.Anti-Bolus etc can be available per customers request
Specification:
Injection Speed:
       - 50(60)ml Syringe 0.1ml/h---1500ml/h (0.1ml/h step)
       - 30ml Syringe 0.1ml/h---900ml/h (0.1ml/h step)
       - 20ml Syringe 0.1ml/h---600ml/h (0.1ml/h step)
       - 10mlsyringe 0.1ml/h---300ml/h (0.1ml/h step)
Rate Accuracy                 within±3% (after correct calibration)
Mechanical Accuracy      within±2Purge RateÂ
       - 50(60)ml Syringe: 1500ml/h
       - 30ml Syringe: 900ml/h
       - 20ml Syringe: 600ml/h
       10ml Syringe: 300ml/h                                                                                                                          Bolus RateÂ
       - 50(60)ml Syringe: 1200ml/h
       - 30ml Syringe: 720ml/h
       - 20ml Syringe: 480ml/h
       - 10ml Syringe: 240ml/h
Volume Limit    0.1ml---999.9ml (0.1ml step)
Total Injection  0.1ml---9999.9ml (0.1ml step)
Occlusion Â
       - High         800mmHg±200mmHg(106.7kPa±26.7kPa)
       - Medium   500mmHg±100mmHg(66.7kPa±13.3kPa)
       - Low          300mmHg±100mmHg(40.7kPa±13.3kPa)
Alarms        - injection soon finish end of injection occlusion improperly
                    - installation of syringe wrong setting low battery etc
Power source     - 100V---240V 50/60Hz Internal rechargeable Li battery
                            - volume≥1,600mAh  4 hours internal battery backup; DC 12V
KVO Speed         - 1ml/h, can be modified from 0.1 to 10ml/h
Power Consumption      15VA
Operation EnvironmentÂ
                           a) Temperature +5---+40degree
                           b) Humidity  20---90% Â
                           c) Atmospheric Pressure  86.0KPa---106.0KPa
Storage              a)Temperature  -30---+55degree
                           b)Humidity  ≤95%
                           c)Atmospheric Pressure  50.10KPa---106.0KPa
Dimension       280mm(L)x 210mm(W)x 130mm(H)
Weight             2.2KG
Syringe            compatible with any brand
Drug library    more than 1000 drug names
Package          1pc for each Carton, 3.2KG; 35cm (L) × 28cm (W) × 17cm (H)
                         2pc carton,6.6KG; 40cm (L) × 39cm (W) × 32cm (H)
                         3pc carton, 10KG; 59cm (L) × 39cm (W) × 32cm (H)
Al Fakher Hookah,Glass Hookah,Shisha Hookah
Fenghua Jade Motor Co., Ltd. , http://www.qiuzanhookah.com