Model NO.: T-Bil
Application: Hospital, Lab, School
Trademark: Biomedia
Specification: R1: 2*60 mL, R2: 2*15 mL
Origin: Jinan, Shandong
Model NO.: T-Bil
Application: Hospital, Lab, School
Trademark: Biomedia
Specification: R1: 2*60 mL, R2: 2*15 mL
Origin: Jinan, Shandong
Total Bilirubin (T-Bil) assay kit is applied to measure the concentration of T-Bil in human serum or plasma.Testing Principle
In the presence of surfactant and accelerating agents, bilirubin can be oxidized by sodium nitrate and converted into biliverdin, which leads to a decrease in absorbance at 450 nm. Total bilirubin concentrations can be calculated from the absorbance change measured at 450 nm.
  Â
Product Features
Â
1. Linear range of T-Bil level: [1, 684] μmol/L
Linear correlation coefficient ∣r∣≥0.990Linear deviation ≤ ± 10.00%
2. Absorbance of blank ≤ 0.10 Â
3. Sensitivity
The change in absorbance (ΔmA) ≥ 0.30 while testing the specific T-Bil sample of concentration of 83.1 μmol/L.4. Accuracy
Relative deviation is within ±10%.5. Precision
Intra CV% ≤ 5.0%; inter CV% ≤5.0%.Technical Parameters
Â
Temperature | 37ºC | Optical path length (OPL) | 1.0 cm |
Main wavelength | 450 nm | Secondary wavelength | 546 nm (Optional) |
Method |
End-point method (dual reagents) |
Reaction direction | Negative |
Sample | 8 μL | R1 | 240 μL |
R2 | 60 μL | Reaction time | 300 s |
Packing Specifications
R1: 2×60 ml, R2: 2×15 ml
R1: 4×60 ml, R2: 4×15 ml
R1: 1×40 ml, R2: 1×10 ml (Sample)
Storage and Stability
Unopened: Store assay kits at 2 - 8ºC protected from light. Stable to expiration date printed on individual vials (for 16 months).
Opened: Store assay kits at 2 - 8ºC protected from light. Stable for 1 month if kept capped from original container and free from contamination.
Do not freeze the assay kit.
 Total Bilirubin (T-Bil) assay kit is applied to measure the concentration of T-Bil in human serum or plasma.
Testing Principle
In the presence of surfactant and accelerating agents, bilirubin can be oxidized by sodium nitrate and converted into biliverdin, which leads to a decrease in absorbance at 450 nm. Total bilirubin concentrations can be calculated from the absorbance change measured at 450 nm.
  Â
Product Features
Â
1. Linear range of T-Bil level: [1, 684] μmol/L
Linear correlation coefficient ∣r∣≥0.990Linear deviation ≤ ± 10.00%
2. Absorbance of blank ≤ 0.10 Â
3. Sensitivity
The change in absorbance (ΔmA) ≥ 0.30 while testing the specific T-Bil sample of concentration of 83.1 μmol/L.4. Accuracy
Relative deviation is within ±10%.5. Precision
Intra CV% ≤ 5.0%; inter CV% ≤5.0%.Technical Parameters
Â
Temperature | 37ºC | Optical path length (OPL) | 1.0 cm |
Main wavelength | 450 nm | Secondary wavelength | 546 nm (Optional) |
Method |
End-point method (dual reagents) |
Reaction direction | Negative |
Sample | 8 μL | R1 | 240 μL |
R2 | 60 μL | Reaction time | 300 s |
Packing Specifications
R1: 2×60 ml, R2: 2×15 ml
R1: 4×60 ml, R2: 4×15 ml
R1: 1×40 ml, R2: 1×10 ml (Sample)
Storage and Stability
Unopened: Store assay kits at 2 - 8ºC protected from light. Stable to expiration date printed on individual vials (for 16 months).
Opened: Store assay kits at 2 - 8ºC protected from light. Stable for 1 month if kept capped from original container and free from contamination.
Do not freeze the assay kit.
Â
The fish fat of mackerel has the functions of lowering blood fat, cholesterol and preventing cardiovascular diseases and prostate cancer. Eating more fish is good for health and can also supplement the lack of iron in the human body. For children and the elderly, mackerel It is the most suitable for them to eat and easy to supplement the required nutrients.